NEUBrew Network Instrument Calibrations/Characterizations


Ozone Calibrations

Brewer UID
Calibration Date
Notes
BR101 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR105 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR108 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR131 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR131 2013-05-26 Ozone Calibrarion performed by Volodya Savastiouk of International Ozone Services (IOS)
BR131 2014-10-19 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
BR132 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR134 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR134 2013-05-26 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
BR134 2014-10-19 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
BR135 2014-10-19 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
BR139 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR139 2014-10-19 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
BR140 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR140 2014-10-19 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
BR141 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR141 2014-10-19 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
BR144 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR144 2014-10-19 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
BR146 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR146 2014-10-19 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
BR147 2006-08-20 Ozone Calibration performed by Ken Lamb from IOS.
BR147 2014-10-19 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
BR154 2007-02-28 Ozone Calibration performed by Ken Lamb from IOS.
BR154 2013-05-26 Ozone Calibrarion performed by Volodya Savastiouk of International Ozone Services (IOS)
BR154 2014-10-19 Ozone Calibration performed by Volodya Savastiouk of International Ozone Services (IOS)
Record Count: 26

UV-B Calibrations


Calib UID
Brewer UID
Calibration Date
Notes
30 BR134 2007-04-18 Spectral Responsivity calibration performed by P Disterhoft. Lamps used were H-025 and H-027 in diffuse and total signal.
41 BR134 2008-08-21 UV-B Calibration performed by Patrick Disterhoft from CUCF. Lamps used H-041 and H-027
49 BR134 2010-09-22 UV-B Calibration performed by Patrick Disterhoft.
31 BR139 2007-04-18 Spectral Responsivity calibration performed by P Disterhoft. Lamps used were H-025 and H-027 in diffuse and total signal measurements. UV Cal not valid after 2007-08-09 when nickel sulfide filter replaced by UG-11x filter.
39 BR139 2007-08-10 Artificial UV responsivity generated from CI Scan Ratios after the Nickle Suphate Filter swapped out for UG-11.
40 BR139 2008-02-12 Artificial UV responsivity generated from CI Scan Ratios after an single UG-11 Filter swapped out for back to back UG-11 filters.
17 BR140 2006-10-13 UV-B Calibration performed by Patrick Disterhoft after Brewer installed at Raleigh, NC.
36 BR140 2007-10-04 UV-B Calibration performed by Patrick Disterhoft at Raleigh, NC.
51 BR140 2010-10-13 UV-B Calibration performed by Patrick Disterhoft.
54 BR140 2011-10-06 UV-B Calibration performed by Patrick Disterhoft.
32 BR141 2007-04-18 Spectral Responsivity calibration performed by P Disterhoft. Lamp sequence:H-041, H-025, H-027; both diffuse and total scan measurements.
42 BR141 2008-08-21 UV-B Calibration performed by Patrick Disterhoft from CUCF. Lamps used H-041 and H-027
46 BR141 2009-03-19 UV-B Calibration performed by Patrick Disterhoft from CUCF. Lamp used H-041
15 BR144 2006-09-24 UV-B Calibration performed by Patrick Disterhoft after Brewer was installed at the Bondville, IL.
33 BR144 2007-06-20 UV-B Calibration performed by Patrick Disterhoft.
43 BR144 2008-08-29 UV Calibration Performed by Patrick Disterhoft. Lamps used H038, H027, H041.
52 BR144 2011-09-14 UV-B Calibration performed by Patrick Disterhoft.
24 BR146 2007-03-27 UV-B Calibration performed by Patrick Disterhoft from CUCF.
37 BR146 2007-11-06 Calibration performed by Patrick Disterhoft at the MRS.
38 BR146 2008-02-21 UV-B Calibration Performed by Patrick Disterhoft
47 BR146 2009-04-08 UV-B Calibration performed by Patrick Disterhoft from CUCF. Lamp used H-041
48 BR146 2010-09-09 UV-B Calibration performed by Patrick Disterhoft.
53 BR146 2011-09-26 UV-B Calibration performed by Patrick Disterhoft.
77 BR146 2014-10-30 UV-B Calibration performed by Patrick Disterhoft.
20 BR147 2006-11-06 UV-B Calibration performed by Patrick Disterhoft after Brewer was installed at Ft. Peck, MT.
34 BR147 2007-09-27 UV-B Calibration performed by Patrick Disterhoft Brewer Temperature 25.4 C.
50 BR147 2010-09-29 UV-B Calibration performed by Scott Stierle.
55 BR147 2011-10-21 UV-B Calibration performed by Patrick Disterhoft.
58 BR147 2012-08-22 UV-B Calibration performed by Patrick Disterhoft. For the August 22, 2012 calibration, the lamps were run in the following order: H-060, H-041, H-058, H-059. Their irradiances were determined during the CUCF scale transfer #76. The average temperature of the Brewer during the four lamp calibrations was 32.81 degrees C.
59 BR147 2013-10-03 UV-B Calibration performed by Patrick Disterhoft. For the October 3, 2013 calibration, the lamps were run in the following order: H-058, H-059 and H-041. Their irradiances were determined during the CUCF scale transfer #87. The average temperature of the Brewer during the three lamp calibrations was 14.01 degrees C.
78 BR147 2014-11-05 UV-B Calibration performed by Scott Stierle from CUCF. Lamps run H-062, H-066, and H-070. Average Brewer Temperature during calibration was 10 degrees C.
13 BR154 2006-07-21 UV-B Calibration performed by Patrick Disterhoft after Brewer was installed at Houston, TX.
23 BR154 2007-03-01 UV-B Calibration performed by Patrick Disterhoft from CUCF.
56 BR154 2011-12-09 UV-B Calibration performed by Patrick Disterhoft.
57 BR154 2013-06-06 UV-B Calibration performed by Patrick Disterhoft.
Record Count: 35

Cosine Measurements

Brewer UID
Calibration Date
Notes
BR134 2007-02-15 Cosine Measurement performed by Patrick Disterhoft at DSRC.
BR139 2007-01-24 Cosine Measurement performed by Patrick Disterhoft at DSRC.
BR140 2006-10-01 Cosine Measurement performed by Patrick Disterhoft at DSRC prior to the Brewer being packed up and shipped to the Raleigh NC site.
BR141 2007-03-12 Cosine Measurement performed by Patrick Disterhoft at DSRC.
BR144 2006-09-18 Cosine Measurement performed by Patrick Disterhoft at DSRC.
BR146 2006-10-09 Cosine Measurement performed by Patrick Disterhoft at DSRC.
BR147 2006-10-25 Cosine Measurement performed by Patrick Disterhoft at DSRC.
BR154 2006-07-15 Cosine Measurement performed by Patrick Disterhoft at DSRC prior to deployment to Houston, TX.
Record Count: 8

Spectral Lamp Measurements

Brewer UID
Calibration Date
Notes
BR134 2007-02-01 External HG,CD,ZN Lamps Scanned; Brewer internal HG Lamp Scanned. Measurments made at DSRC.
BR139 2007-01-25 External HG,CD,ZN Lamps Scanned; Brewer internal HG Lamp Scanned. Measurments made at DSRC.
Record Count: 2