07-aug-10 21:01:16 Measurements ended --- . Number of lamps (L) = 7 . Filter running time = 96.5 hours . Total airflow this filter = 28.32 cubic meters . Mean BC concentration of all lamps = 10 ng/m3 . Report for lamp 1 (370 nm): . Ending voltages: sen(beam) = 1.067 sen(zero) = 0.021 . ref(beam) = 2.151 ref(zero) = 0.021 . Optical attenuation of filter deposit = 24 . Total aerosol black carbon on filter = 305 ng Mean aerosol black carbon concentration = 10 ng/m3 --- The reference beam showed lamp intensity fluctuations of 296 ppm. --- Report for lamp 2 (470 nm): . Ending voltages: sen(beam) = 1.746 sen(zero) = 0.021 . ref(beam) = 2.268 ref(zero) = 0.021 . Optical attenuation of filter deposit = 18 . Total aerosol black carbon on filter = 304 ng Mean aerosol black carbon concentration = 10 ng/m3 --- The reference beam showed lamp intensity fluctuations of 289 ppm. --- Report for lamp 3 (520 nm): . Ending voltages: sen(beam) = 1.233 sen(zero) = 0.021 . ref(beam) = 2.433 ref(zero) = 0.021 . Optical attenuation of filter deposit = 16 . Total aerosol black carbon on filter = 294 ng Mean aerosol black carbon concentration = 10 ng/m3 --- The reference beam showed lamp intensity fluctuations of 301 ppm. --- Report for lamp 4 (590 nm): . Ending voltages: sen(beam) = 1.613 sen(zero) = 0.021 . ref(beam) = 1.165 ref(zero) = 0.021 . Optical attenuation of filter deposit = 14 . Total aerosol black carbon on filter = 293 ng Mean aerosol black carbon concentration = 10 ng/m3 --- The reference beam showed lamp intensity fluctuations of 494 ppm. --- Report for lamp 5 (660 nm): . Ending voltages: sen(beam) = 2.410 sen(zero) = 0.021 . ref(beam) = 2.600 ref(zero) = 0.021 . Optical attenuation of filter deposit = 13 . Total aerosol black carbon on filter = 304 ng Mean aerosol black carbon concentration = 10 ng/m3 --- The reference beam showed lamp intensity fluctuations of 422 ppm. --- Report for lamp 6 (880 nm): . Ending voltages: sen(beam) = 2.092 sen(zero) = 0.021 . ref(beam) = 3.357 ref(zero) = 0.021 . Optical attenuation of filter deposit = 11 . Total aerosol black carbon on filter = 336 ng Mean aerosol black carbon concentration = 11 ng/m3 --- The reference beam showed lamp intensity fluctuations of 459 ppm. --- Report for lamp 7 (950 nm): . Ending voltages: sen(beam) = 1.655 sen(zero) = 0.021 . ref(beam) = 4.424 ref(zero) = 0.021 . Optical attenuation of filter deposit = 10 . Total aerosol black carbon on filter = 327 ng Mean aerosol black carbon concentration = 11 ng/m3 --- The reference beam showed lamp intensity fluctuations of 468 ppm. --- Disk space = 1.637222E+07 bytes free: One entry at every 5 minutes. There is space for 3480 hours ( 145 days) more data ---